-You may want to reprocess your spectroscopic data. This can be done on the **observer5** computer. The necessary software is installed in /​opt/​EffelsbergSpecPipeline. There is a bash script to set all the necessary paths. tcsh shell users should change to bash by typing bash. The teleskop, obs2 account are already bash accounts. Launch the following command:\\ 
-\\ 
-**source /​opt/​EffelsbergSpecPipeline/​init_classwriter.sh**\\ 
-\\ 
-Now you should be ready to run the Offline Calibration pipeline. Type\\ 
-\\  
-**OfflinePipeline**\\ 
-\\ 
-Now you are in an ipython interface to reduce the data. There are the following commands to reduce the data:\\ 
-\\ 
- 
-**setFitsDir('/​daten/​Raw'​)**\\ 
-\\ 
-Set the source directory for the rawdata. The program looks in the directory for the raw mbfits files.\\ 
-\\ 
-**setClassName('​Filename','​Directory'​)**\\ 
-\\ 
-this sets the output gildas, class file. if only:\\ 
-\\ 
-**setClassName('​Filename'​)**\\ 
-\\ 
-is given, the named file is created in the current dictionary. Without this command 
-a file name e.g. like class_2010_10_20.100m is created in the current directory. 
-To write the files one has to know the scan number and must give the subscan number. 
-Subscan numbers are 1 based. If the subscan is not in the file an error is plotted.\\ 
-\\ 
-**reduceSubscan(scannumber,​subscannumber)**\\ 
-\\ 
-If you reduce the same scan twice, it is written twice to the class file with the same scan number. You can investigate the result with [[information_for_astronomers:​using_class_on_observer3_computer_in_effelsberg|]]\\ 
-\\ 
-**fixFFTSRefChannel(shiftFFTSRefChannel=True)**\\ 
-\\ 
-Before February 2011 the reference channel of the FFTS has to be shifted by +0.5 channels if the spectrum was not if flipped, otherwise -0.5 channels.\\ 
-\\ 
-**flipArrayOrientation(reverseArrayOrientation=True)**\\ 
-\\ 
-This function flips the dataArrays for the following reduce operations. 
- 
- 
  