User Tools

Site Tools


information_for_astronomers:rx:p170mm

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
information_for_astronomers:rx:p170mm [2024/09/09 09:03]
akraus
information_for_astronomers:rx:p170mm [2025/06/04 18:19] (current)
akraus
Line 25: Line 25:
  
 **Comments:​** **Comments:​**
-  * The system delivers two basebands, 1.3-2.6 GHz and 3.0-6.0 GHz. Currently, it is not possible to record both basebands ​in parallel for continuum or spectroscopic observations. +  * The system delivers two basebands, 1.3-2.6 GHz and 3.0-6.0 GHz. Currently, it is only possible to record both bands in parallel ​for pulsar observations (timing and search mode), but not yet for continuum or spectroscopic observations. 
 +  * Usable / useful continuum bands are e.g. 1.405-1.415 GHz, 1.66-1.67 GHz, 4.7-5.0 GHz, 5.3-5.6 GHz.
  
 +  ​
 ==== Available receiver versions (for OBSINP) ==== ==== Available receiver versions (for OBSINP) ====
  
Line 33: Line 34:
 |EDDPOL | spectro-polarimeter backend for continuum observations in the lower band|with 64k channels | |EDDPOL | spectro-polarimeter backend for continuum observations in the lower band|with 64k channels |
 |EDDPOL3G | spectro-polarimeter backend for continuum observations in the upper band|with 64k channels | |EDDPOL3G | spectro-polarimeter backend for continuum observations in the upper band|with 64k channels |
-|EDD_PULSAR| pulsar ​backend ​| |+|EDD_PULSAR_TIMING| pulsar ​folding mode observations ​coherent dedispersion,​ configurable channels and subints | 
 +|EDD_PULSAR_SEARCH| pulsar search mode observations ​ | coherent filterbank, configurable channels and time samples (down to 32$\mu$s) ​|
   ​   ​
  
  
  
information_for_astronomers/rx/p170mm.1725865416.txt.gz · Last modified: 2024/09/09 09:03 by akraus