User Tools

Site Tools


information_for_astronomers:rx:s110mm

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
information_for_astronomers:rx:s110mm [2024/06/29 11:00]
akraus
information_for_astronomers:rx:s110mm [2024/07/10 16:22] (current)
akraus
Line 20: Line 20:
 **Comments:​** **Comments:​**
   * The values for LCP and RCP do not differ significantly.   * The values for LCP and RCP do not differ significantly.
-  * A typical value for the zenith opacity is 0.010.+  * A typical value for the zenith opacity is 0.01.
  
 ==== Available receiver versions (for OBSINP) ==== ==== Available receiver versions (for OBSINP) ====
  
-^Version^Description^Usage+^Version^Description^Details
-|EDDPOL | spectro-polarimeter backend ​continuum observations| +|EDDPOL | spectro-polarimeter backend ​for continuum observations
-|EDD_GSPEC| gated spectrometer with xx channels ​| spectroscopy+|EDD_GSPEC| gated spectrometer ​with xx channels ​ 
-|EDD_GSPEC_128k| gated spectrometer with 128k channels ​| spectroscopy+|EDD_GSPEC_128k| gated spectrometer ​with 128k channels |  
-|EDD_GSPEC_512k| gated spectrometer with 512k channels ​| spectroscopy+|EDD_GSPEC_512k| gated spectrometer ​with 512k channels |  
-|EDD_PULSAR| pulsar backend | pulsars / transients|+|EDD_PULSAR| pulsar backend | |
  
 **Below here: Information is currently updated. **Below here: Information is currently updated.
information_for_astronomers/rx/s110mm.1719651629.txt.gz · Last modified: 2024/06/29 11:00 by akraus