If you want to reduce your (spectroscopic and pointing) data with class one should use the observer6 or observer9 or observer10 computer. Everyone with an account in the mpifr network can login to this computer with his/her account. It is connected to the /homes server. It is also connected to /homes/astro/gag, so your gildas packeage of choice should work. It is also possible to use a local version of class, which is used to write the spectroscopic and pointing data. to enable this change to the bash shell by typing bash and source the init file:
source /opt/bin/init_class.sh
afterward you can try to run
class
the Data from the pipeline is stored in /daten/Class on be4 and after a time also at /eff/data (especially for
access from Bonn). To open the file:
las90> file in "/eff/data/Class/fw_class_2018-12-11_03-18.100m"
las90> find
for pointings you have to switch to continuum mode:
las90> set type c
cas90> find
to switch back for line observations:
cas90> set type l
las90> find
To look for new data type and wait:
las90> new
You can of course write out your spectra to a new file. You have to specify it with:
las90> file out myFile.100m mult